75W DIN Rail Power Supply DR-75

75W DIN Rail Power Supply DR-75

Features:

  • Universal AC input/Full range
  • Protections: Short circuit/Over load/Over voltage/Over temperature
  • Cooling by free air convection
  • Can be installed on DIN rail TS-35/7.5 or 15
  • LED indicator for power on
  • 100% full load burn-in test
  • Fix switching frequency at 50KHz

Description

75W DIN Rail Power Supply DR-75 Technical Data

MODELDR-75-12DR-75-24DR-75-48
OUTPUTDC VOLTAGE12V24V48V
RATED CURRENT6.3A3.2A1.6A
CURRENT RANGE0 ~ 6.3A0 ~ 3.2A0 ~ 1.6A
RATED POWER76W76.8W76.8W
RIPPLE & NOISE (max.) Note.2100mVp-p150mVp-p240mVp-p
VOLTAGE ADJ. RANGE12 ~ 14V24 ~ 28V48 ~ 53V
VOLTAGE TOLERANCE Note.3±2.0%±1.0%±1.0%
LINE REGULATION±0.5%±0.5%±0.5%
LOAD REGULATION±1.0%±1.0%±1.0%
SETUP, RISE TIME1000ms, 60ms/230VAC   1800ms, 60ms/115VAC at full load
HOLD TIME(Typ.)60ms/230VAC      12ms/115VAC at full load
INPUTVOLTAGE RANGE85 ~ 264VAC       120 ~ 370VDC
FREQUENCY RANGE47 ~ 63Hz
EFFICIENCY (Typ.)76%80%81%
AC CURRENT1.6A/115VAC     0.96A/230VAC
INRUSH CURRENT (max.)COLD START 20A/115VAC 40A/230VAC
LEAKAGE CURRENT<1mA/240VAC
PROTECTIONOVERLOAD105 ~ 150% rated output power
Protection type: Constant current limiting,recovers automatically after fault condition is removed
OVER VOLTAGE15 ~ 16.5V29 ~ 34V58 ~ 65V
Protection type: Hiccup mode, recovers automatically after fault condition is removed
OVER TEMPERATURE85ºC±5ºC (TSW1) Detect on heat sink of power transistor
Protection type: Shut down o/p voltage, recovers automatically after temperature goes down
ENVIRONMENTWORKING TEMP.-10 ~ +60ºC
WORKING HUMIDITY20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY-20 ~ +85ºC, 10 ~ 95% RH
TEMP. COEFFICIENT±0.03%/ºC (0 ~ 50ºC)
VIBRATION10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC (Note 4)SAFETY STANDARDSDesign refer to UL508, TUV EN60950-1
WITHSTAND VOLTAGEI/P-O/P:3KVAC     I/P-FG:1.5KVAC     O/P-FG:0.5KVAC
ISOLATION RESISTANCEI/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMI CONDUCTION & RADIATIONCompliance to EN55022 (CISPR22) Class B
HARMONIC CURRENTCompliance to EN61000-3-2,-3
EMS IMMUNITYCompliance to EN61000-4-2,3,4,5,6,8,11, ENV50204, EN55024, EN61000-6-2 (EN50082-2) Heavy industry level, criteria A
OTHERSMTBF123.1K hrs min. MIL-HDBK-217F (25ºC)
DIMENSION55.5*125.2*100mm (L*W*H)
PACKING0.6Kg; 20pcs/13Kg/1.1CUFT
NOTE1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance: includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into final equipment. The final equipment must be re-confirmed that it still meets EMC directives.

75W DIN Rail Power Supply DR-75 Mechanical

75W DIN Rail Power Supply DR-75 Mechanical

75W DIN Rail Power Supply DR-75 Certificate

LVD Certificate
EMC Certificate
RoHS Certificate