65W Open Frame Power Supply PS-65

65W Open Frame Power Supply PS-65

Features:

  • Universal AC input/Full range
  • Low leakage current<0.5mA
  • Protections: Short circuit/Over load/Over voltage
  • Cooling by free air convection
  • 100% full load burn-in test
  • Fixed switching frequency at 65KHz

Description

65W Open Frame Power Supply PS-65 Technical Data

MODELPS-65-3.3PS-65-5PS-65-7.5PS-65-12PS-65-13.5PS-65-15PS-65-24PS-65-27PS-65-48
OUTPUTDC VOLTAGE3.3V5V7.5V12V13.5V15V24V27V48V
RATED CURRENT12A12A8A5.2A4.7A4.2A2.7A2.4A1.35A
CURRENT RANGE0 ~ 15.2A0 ~ 13.8A0 ~ 9.6A0 ~ 6A0 ~ 5.4A0 ~ 4.8A0 ~ 3A0 ~ 2.7A0 ~ 1.5A
RATED POWER39.6W60W60W62.4W63.5W63W64.8W64.8W64.8W
OUTPUT POWER (max.)Rated output power for convection; 72W (+3.3V: 50W;+5V: 69W) with 18 CFM min. Forced air
RIPPLE & NOISE (max.) Note.280mVp-p100mVp-p100mVp-p100mVp-p100mVp-p100mVp-p100mVp-p100mVp-p100mVp-p
VOLTAGE ADJ. RANGE3.14 ~ 3.63V4.75 ~ 5.5V7.13 ~ 8.25V11.4 ~ 13.2V12.8 ~ 14.9V14.25 ~ 16.5V22.8 ~ 26.4V25.65 ~ 29.7V45.6 ~ 52.8V
VOLTAGE TOLERANCE Note.3±3.0%±3.0%±3.0%±2.0%±2.0%±2.0%±2.0%±2.0%±2.0%
LINE REGULATION±1.0%±1.0%±1.0%±1.0%±1.0%±1.0%±1.0%±1.0%±1.0%
LOAD REGULATION±3.0%±3.0%±3.0%±2.0%±2.0%±2.0%±2.0%±2.0%±2.0%
SETUP, RISE, HOLD TIME800ms, 20ms, 60ms at full load
INPUTVOLTAGE RANGE90 ~ 264VAC          127 ~ 370VDC
FREQUENCY RANGE47 ~ 440Hz
EFFICIENCY (Typ.)69%76%79%79%79%79%80%80%80%
AC CURRENT1.2A/115VAC      0.72A/230VAC
INRUSH CURRENT (max.)COLD START 20A/115VAC         40A/230VAC
LEAKAGE CURRENT<0.5mA/240VAC
PROTECTIONOVERLOAD73 ~ 105W (3.3V: 51 ~ 75 W) (5V: 70 ~ 105) rated output power
Protection type: Hiccup mode, recovers automatically after fault condition is removed.
OVER VOLTAGE3.8 ~ 4.46V5.75 ~ 6.75V8.63 ~ 10.1V13.8 ~ 16.2V15.5 ~ 18.2V17.25 ~ 20.25V27.6 ~ 32.4V31 ~ 36.45V55.2 ~ 64.8V
Protection type: Hiccup mode, recovers automatically after fault condition is removed.
ENVIRONMENTWORKING TEMP.-10 ~ +60ºC
WORKING HUMIDITY20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY-20 ~ +85ºC, 10 ~ 95% RH
TEMP. COEFFICIENT±0.04%/ºC (0 ~ 50ºC)
VIBRATION10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC(Note4)SAFETY STANDARDSDesign refer to UL60950-1, TUV EN60950-1
WITHSTAND VOLTAGEI/P-O/P: 3KVAC  I/P-FG: 1.5KVAC  O/P-FG: 0.5KVAC
ISOLATION RESISTANCEI/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMI CONDUCTION & RADIATIONCompliance to EN55022 (CISPR22) Class B
HARMONIC CURRENTCompliance to EN61000-3-2,-3
EMS IMMUNITYCompliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A
OTHERSMTBF300.7Khrs min. MIL-HDBK-217F(25ºC)
DIMENSION127*76*42mm (L*W*H)
PACKING0.21Kg; 54pcs/14.2Kg/1.35CUFT
NOTE1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºCof ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance: includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
5.Mounting holes M1 and M2 should be grounded for EMI purposes.

65W Open Frame Power Supply PS-65 Mechanical

65W Open Frame Power Supply PS-65 Mechanical

65W Open Frame Power Supply PS-65 Certificate

LVD Certificate
65W Open Frame Power Supply PS-65 LVD Certificate
EMC Certificate
65W Open Frame Power Supply PS-65 EMC Certificate
RoHS Certificate
Open Frame Power Supply RoHS

Send message