60W Waterproof Power Supply SV-60

60W Waterproof Power Supply SV-60

Features:

  • Protections: Short circuit/Over load
  • 100% full load burn-in
  • Lost cost
  • High reliability
  • Waterproof and moisture proof
  • Convenient wiring

Description

60W Waterproof Power Supply SV-60 Technical Data

MODELSV-60-5SV-60-12SV-60-15SV-60-24SV-60-48
OUTPUTDC VOLTAGE5V12V15V24V48V
RATED CURRENT12A5A4A2.5A1.25A
CURRENT RANGE0 ~ 12A0 ~ 5A0 ~ 4A0 ~ 2.5A0 ~ 1.25A
RATED POWER60W60W60W60W60W
RIPPLE & NOISE (max.) Note.280mVp-p120mVp-p150mVp-p200mVp-p240mVp-p
VOLTAGE TOLERANCE Note.3±2.0%±1.0%±1.0%±1.0%±1.0%
LINE REGULATION±0.5%±0.5%±0.5%±0.5%±0.5%
LOAD REGULATION±0.5%±0.5%±0.5%±0.5%±0.5%
SETUP, RISE, HOLD TIME500ms, 30ms, 50ms/230VAC  1200ms, 30ms, 10ms/115VAC at full load
INPUTVOLTAGE RANGE85 ~ 264VAC   120 ~ 373VDC
FREQUENCY RANGE47 ~ 63Hz
EFFICIENCY (Typ.)77%82%83%86%87%
AC CURRENT(Typ.)1.2A/115VAC  0.8A/230VAC
INRUSH CURRENT (Typ.)COLD START 60A
LEAKAGE CURRENT<2mA / 240VAC
PROTECTIONOVERLOAD110 ~ 150% rated output power
Protection type: Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE5.75 ~ 6.75V13.8 ~ 16.2V17.25 ~ 20.25V27.6 ~ 32.4V55.2 ~ 64.8V
Protection type: Hiccup mode, recovers automatically after fault condition is removed
ENVIRONMENTWORKING TEMP.-30 ~ +75ºC
WORKING HUMIDITY20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY-40 ~ +85ºC, 10 ~ 95% RH
TEMP. COEFFICIENT±0.03%/ºC (0 ~ 50ºC)
VIBRATION10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY & EMC(Note.4)SAFETY STANDARDSDesign refer to UL60950-1,TUV EN60950-1
WITHSTAND VOLTAGEI/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCEI/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMI CONDUCTION & RADIATIONCompliance to EN55022(CISPR22) Class B
HARMONIC CURRENTCompliance to EN61000-3-2,-3
EMS IMMUNITYCompliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61000-6-2 (EN50082-2) heavy industry level, criteria A
OTHERSMTBF378.2Khrs min. MIL-HDBK-217F (25ºC)
DIMENSION180*68*53(L*W*H)
PACKING0.8Kg; 10pcs/8.5Kg/0.0135CBM
NOTE1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3. Tolerance: includes set up tolerance, line regulation and load regulation.

4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.

60W Waterproof Power Supply SV-60 Mechanical

60W Waterproof Power Supply SV-60 Certificate

LVD Certificate
60W Waterproof Power Supply SV-60 LVD Certificate
EMC Certificate
60W Waterproof Power Supply SV-60 EMC Certificate
RoHS Certificate
Waterproof Power Supply SV RoHS

Send message