60W Dual Output Switching Power Supply D-60

60W Dual Output Switching Power Supply D-60

Features:

  • Universal AC input/Full range
  • Protections: Short circuit/Over load/Over voltage
  • Cooling by free air convection
  • LED indicator for power on
  • Fixed switching frequency at 54KHz

Description

60W Dual Output Switching Power Supply D-60 Technical Data

MODELD-60AD-60B
OUTPUTOUTPUT NUMBERCH1CH2CH1CH2
DC VOLTAGE5V12V5V24V
RATED CURRENT4A3A3A1.8A
CURRENT RANGE0.3 ~ 6A0.2 ~ 4A0.3 ~ 6A0.2 ~ 2.2A
RATED POWER56W58W
RIPPLE & NOISE (max.) Note.275mVp-p150mVp-p75mVp-p150mVp-p
VOLTAGE ADJ. RANGECH1: 4.75 ~ 5.5VCH1: 4.75 ~ 5.5V
VOLTAGE TOLERANCE Note.3±2.0%±6.0%±2.0%±5.0%
LINE REGULATION±0.5%±1.0%±0.5%±0.5%
LOAD REGULATION±0.5%±4.0%±0.5%±4.0%
SETUP, RISE, HOLD TIME300ms, 50ms, 80ms/230VAC   800ms, 50ms, 10ms/115VAC at full load
INPUTVOLTAGE RANGE85 ~ 264VAC       120 ~ 370VDC
FREQUENCY RANGE47 ~ 63Hz
EFFICIENCY (Typ.)73%76%
AC CURRENT2A/115VAC 1A/230VAC
INRUSH CURRENT (max.)COLD START 20A/115VAC 40A/230VAC
LEAKAGE CURRENT<3.5mA / 240VAC
PROTECTIONOVERLOAD105 ~ 150% rated output power.
Protection type: Hiccup mode, recovers automatically after fault condition is removed.
OVER VOLTAGE5V: 5.75 ~ 6.75V
Protection type: Hiccup mode, recovers automatically after fault condition is removed.
ENVIRONMENTWORKING TEMP.-10 ~ +60ºC
WORKING HUMIDITY20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY-20 ~ +85ºC, 10 ~ 95% RH
TEMP. COEFFICIENT±0.03%/ºC (0 ~ 50ºC) on +5V output
VIBRATION10 ~ 500Hz, 2G 10min./1cycle,period for 60min. each along X, Y, Z axes
SAFETY & EMC (Note 4)SAFETY STANDARDSDesign refer to UL1012, UL60950, TUV EN60950
WITHSTAND VOLTAGEI/P-O/P: 3KVAC  I/P-FG: 1.5KVAC  O/P-FG: 0.5KVAC
ISOLATION RESISTANCEI/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMI CONDUCTION & RADIATIONCompliance to EN55022 (CISPR22) Class B
HARMONIC CURRENTCompliance to EN61000-3-2,-3
EMS IMMUNITYCompliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A
OTHERSMTBF301.2K hrs min. MIL-HDBK-217F (25ºC)
DIMENSION159*97*38mm (L*W*H)
PACKING0.47Kg; 30pcs/15.80Kg/0.0250CBM
NOTE1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºCof ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance: includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into final equipment. The final equipment must be re-confirmed that it still meets EMC directives.

60W Dual Output Switching Power Supply D-60 Mechanical

60W Dual Output Switching Power Supply D-60 Certificate

LVD Certificate
60W Dual Output Switching Power Supply D-60 LVD Certificate
EMC Certificate
RoHS Certificate
Switching Power Supply S ROHS

Send message