500W PFC Power Supply SP-500

500W PFC Power Supply SP-500

Features:

  • Universal AC input / Full range
  • Built-in active PFC function, PF>0.95
  • Protections: Short circuit/Over load/Over voltage/Over temperature
  • Forced air cooling by built-in DC fan
  • Built-in cooling Fan ON-OFF control
  • Built-in remote ON-OFF control
  • Built-in remote sense function
  • Fixed switching frequency at 110KHz

Description

500W PFC Power Supply SP-500 Technical Data

MODELSP-500-12SP-500-13.5SP-500-15SP-500-24SP-500-27SP-500-48
OUTPUTDC VOLTAGE12V13.5V15V24V27V48V
RATED CURRENT40A36A32A20A18A10A
CURRENT RANGE0 ~ 40A0 ~ 36A0 ~ 32A0 ~ 20A0 ~ 18A0 ~ 10A
RATED POWER480W486W480W480W486W480W
RIPPLE & NOISE (max.) Note.2240mVp-p240mVp-p240mVp-p240mVp-p200mVp-p300mVp-p
VOLTAGE ADJ. RANGE10 ~ 13.2V12 ~ 15V13.5 ~ 18V20 ~ 26.4V26 ~ 32V41 ~ 56V
VOLTAGE TOLERANCE Note.3±1.0%±1.0%±1.0%±1.0%±1.0%±1.0%
LINE REGULATION±0.5%±0.5%±0.5%±0.5%±0.5%±0.5%
LOAD REGULATION±0.5%±0.5%±0.5%±0.5%±0.5%±0.5%
SETUP, RISE, HOLD TIME1500s, 50ms, 24ms
INPUTVOLTAGE RANGE88 ~ 264VAC          124 ~ 370VDC
FREQUENCY RANGE47 ~ 63Hz
POWER FACTORPF>0.95/115       PF>0.95>240VAC at full load
EFFICIENCY (Typ.)84%84%83%85.5%86.5%87%
AC CURRENT7A/115V        3.5A/230V
INRUSH CURRENT (max.)18A/115V      36A/230V
LEAKAGE CURRENT<3.5mA / 240VAC
PROTECTIONOVERLOAD105 ~ 135% of rate load
Protection type: Fold back current limiting, recovers automatically after fault condition is removed
OVER VOLTAGE13.8 ~ 16.2V15.5 ~ 18.2V18 ~ 21V27.6 ~ 32.4V31 ~ 36.5V57.6 ~ 67.2V
Protection type: Hiccup mode, recovers automatically after fault condition is removed.
FAN CONTROL,O.T.P.RTH1 or RTH2≥50ºC FAN ON,≤45ºC FAN, ≥70ºC output shut down
FUNCTIONREMOTE CONTROLRC+/RC-: Short = power on; Open = power off
ENVIRONMENTWORKING TEMP.-10 ~ +50ºC, 20 ~ 90% RH non-condensing
WORKING HUMIDITY20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY-20 ~ +85ºC, 10 ~ 95% RH
TEMP. COEFFICIENT±0.03%/ºC (0 ~ 50ºC)
VIBRATION10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC(Note 4)SAFETY STANDARDSDesign refer to UL1950, TUV EN60950-1
WITHSTAND VOLTAGEI/P-O/P: 3KVAC   I/P-FG: 1.5KVAC    O/P-FG: 0.5KVAC
ISOLATION RESISTANCEI/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC
EMI CONDUCTION & RADIATIONCompliance to EN55022 (CISPR22) Class B
HARMONIC CURRENTCompliance to EN61000-3-2,-3
EMS IMMUNITYCompliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, Light industry level, criteria A
OTHERSMTBF133.4K hrs min. MIL-HDBK-217F (25ºC)
DIMENSION170*120*93mm (L*W*H)
PACKING1.807Kg/pc, 10pcs/19.53Kgs/0.0326CBM
NOTE1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºCof ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance: includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
5. derating may be needed under low input voltages. Please check the derating curve for more details.

500W PFC Power Supply SP-500 Mechanical

500W PFC Power Supply SP-500 Mechanical

500W PFC Power Supply SP-500 Certificate

LVD Certificate
500W PFC Power Supply SP-500 LVD Certificate
EMC Certificate
500W PFC Power Supply SP-500 EMC Certificate
RoHS Certificate
PFC Power Supply RoHS

Send message