155W Battery Charger Power Supply AD-155

155W Battery Charger Power Supply AD-155 With UPS function

Features:

  • Universal AC input / Full range
  • Protections: Short circuit / Overload / Over voltage
  • Battery low and battery polarity protection
  • Cooling by free air convection
  • 100% full load burn-in test
  • Fixed switching frequency at PFC 67KHz, PWM 134KHz

Description

155W Battery Charger Power Supply AD-155 With UPS function Technical Data

MODELAD-155AAD-155BAD-155C
OUTPUTOUTPUT NUMBERCH1CH2CH1CH2CH1CH2
DC VOLTAGE13.8V13.3V27.6V27.1V54V53.5V
RATED CURRENT10.5A0.5A5A0.5A2.7A0.2A
CURRENT RANGE0 ~ 11.5A———-0 ~ 5.5A———-0 ~ 2.7A0 ~ 0.5A
RATED POWER151.55W151.55W156.5W
RIPPLE & NOISE (max.) Note.2150mVp-p———-150mVp-p———-240mVp-p———-
VOLTAGE ADJ. RANGECH1: 12 ~ 14.5VCH1: 24 ~ 29VCH1: 48 ~ 58V
VOLTAGE TOLERANCE Note.3±2.0%———-±1.0%———-±1.0%———-
LINE REGULATION±0.5%———-±0.5%———-±0.5%———-
LOAD REGULATION±0.5%———-±0.5%———-±0.5%———-
SETUP, RISE, HOLD TIME1000ms, 90ms, 24ms/230VAC    2000ms, 90ms, 20ms/115VAC at full load
INPUTVOLTAGE RANGE88 ~ 264VAC          240 ~ 370VDC
FREQUENCY RANGE47 ~ 63Hz
EFFICIENCY (Typ.)80%84%84%
AC CURRENT2.5A/115VAC        1.5A/230VAC
INRUSH CURRENT (max.)COLD START 20A/115VAC         40A/230VAC
LEAKAGE CURRENT<1mA / 240VAC
PROTECTIONOVERLOADCH1:105 ~ 135%          CH2:0.51 ~ 0.9A rated output power
Protection type: Constant current limiting, recovers automatically after fault condition is reoved
OVER VOLTAGECH1: 15.87 ~ 18.63VCH1: 31.74 ~ 37.26VCH1: 62.1 ~ 72.9V
Protection type: Shut down o/p voltage, re-power on to recover
BATTERY LOW10V ± 0.8V19.5V(+1.5V,-1V )39V±2V
ENVIRONMENTWORKING TEMP.-10 ~ +60℃
WORKING HUMIDITY20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY-20 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT±0.03%/℃ (0 ~ 50℃) on CH1 output
VIBRATION10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMCSAFETY STANDARDSDesign refer to UL60950-1, TUV EN60950-1
WITHSTAND VOLTAGEI/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCEI/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMI CONDUCTION & RADIATIONCompliance to EN55022 (CISPR22) Class B
HARMONIC CURRENTCompliance to EN61000-3-2,-3
EMS IMMUNITYCompliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level,  criteria A
OTHERSMTBF183.3K hrs min. MIL-HDBK-217F (25℃ )
DIMENSION199*110*50mm (L*W*H)
PACKING0.757Kg; 16pcs/13.67Kg/0.0287CBM
NOTE1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance: includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into final equipment. The final equipment must be re-confirmed that it still meets EMC directives.

155W Battery Charger Power Supply AD-155 Mechanical

155W Battery Charger Power Supply AD-155 Mechanical

155W Battery Charger Power Supply AD-155 Certificate

LVD Certificate
155W Battery Charger Power Supply AD-155 LVD Certificate
EMC Certificate
155W Battery Charger Power Supply AD-155 EMC Certificate
RoHS Certificate
Battery Charger Power Supply RoHS

Send message