10W DIN Rail Power Supply MDR-10

10W DIN Rail Power Supply MDR-10

Features:

  • Universal AC input/Full range
  • Protections: Short circuit / Overload / Over voltage
  • Cooling by free air convection
  • Can be installed on DIN rail TS-35/7.5 or 15
  • Built in DC OK active signal
  • LED indicator for power on
  • No load power consumption<0.75W
  • 100% full load burn-in test

Description

10W DIN Rail Power Supply MDR-10 Technical Data

MODELMDR-10-5MDR-10-12MDR-10-15MDR-10-24
OUTPUTDC VOLTAGE5V12V15V24V
RATED CURRENT2A0.84A0.67A0.42A
CURRENT RANGE0 ~ 2A0 ~ 0.84A0 ~0.67A0 ~ 0.42A
RATED POWER10W10W10W10W
RIPPLE & NOISE (max.) Note.280mVp-p120mVp-p120mVp-p150mVp-p
VOLTAGE TOLERANCE Note.3±5.0%±3.0%±3.0%±2.0%
LINE REGULATION±1.0%±1.0%±1.0%±1.0%
LOAD REGULATION±5.0%±3.0%±3.0%±2.0%
SETUP, RISE TIME Note.5500ms, 30ms/230VAC 1000ms, 30ms/115VAC at full load
HOLD TIME(Typ.)120ms/230VAC 25ms/115VAC at full load
INPUTVOLTAGE RANGE85 ~ 264VAC       120 ~ 370VDC
FREQUENCY RANGE47 ~ 63Hz
EFFICIENCY (Typ.)77%81%81%84%
AC CURRENT0.33A/115VAC 0.21A/230VAC
INRUSH CURRENT (max.)COLD START 35A/115VAC 70A/230VAC
PROTECTIONOVERLOADAbove 105% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE5.75 ~ 6.75V13.8 ~ 16.2V17.25 ~ 20.25V27.6 ~ 32.4V
Protection type: Shut down o/p voltage,re-power on to recover
FUNCTIONDC OK ACTIVE SIGNAL (max.)3.75 ~ 6V / 50mA9 ~ 13.5V / 40mA11.5 ~ 16.5V / 40mA18 ~ 27V / 20mA
ENVIRONMENTWORKING TEMP.-20 ~ +70ºC
WORKING HUMIDITY20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY-40 ~ +85ºC, 10 ~ 95% RH
TEMP. COEFFICIENT±0.03%/ºC (0 ~ 50ºC)
VIBRATIONComponent:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6
SAFETY & EMC (Note 4)SAFETY STANDARDSDesign refer to UL508,TUV EN60950-1
WITHSTAND VOLTAGEI/P-O/P:3KVAC     I/P-FG:2KVAC     O/P-FG:0.5KVAC
ISOLATION RESISTANCEI/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC / 25℃/ 70% RH
EMC EMISSIONCompliance to EN55011, EN55022 (CISPR22), EN61204-3 Class B, EN61000-3-2,-3
EMC IMMUNITYCompliance to EN61000-4-2, 3, 4, 5, 6, 8, 11, EN55024,EN61000-6-1,EN61204-3, light industry level, criteria A
OTHERSMTBF584K hrs min. MIL-HDBK-217F (25℃)
DIMENSION22.5*90*100mm (W*H*D)
PACKING0.17Kg; 72pcs/13.2Kg/0.91CUFT
NOTE1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance: includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies”.
5. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time

10W DIN Rail Power Supply MDR-10 Mechanical

10W DIN Rail Power Supply MDR-10 Mechanical

10W DIN Rail Power Supply MDR-10 Certificate

LVD Certificate
EMC Certificate
RoHS Certificate

Send message