100W Switching Power Supply RS-100

100W Switching Power Supply RS-100

Features:

  • Universal AC input / Full range
  • Protections: Short circuit / Overload / Over voltage
  • Cooling by free air convection
  • LED indicator for power on
  • 100% full load burn-in test
  • All using 105℃ long life electrolytic capacitors
  • Withstand 300VAC surge input for 5 second
  • High operating temperature up to 70℃
  • Withstand 5G vibration test
  • High efficiency, long life and high reliability

Description

100W Switching Power Supply RS-100 Technical Data

MODEL RS-100-3.3 RS-100-5 RS-100-12 RS-100-15 RS-100-24 RS-100-48
OUTPUT DC VOLTAGE 3.3V 5V 12V 15V 24V 48V
RATED CURRENT 20A 16A 8.5A 7A 4.5A 2.3A
CURRENT RANGE 0 ~ 20A 0 ~ 16A 0 ~ 8.5A 0 ~ 7A 0 ~ 4.5A 0 ~ 2.3A
RATED POWER 66W 80W 102W 105W 108W 110.4W
RIPPLE & NOISE (max.) Note.2 80mVp-p 80mVp-p 120mVp-p 120mVp-p 120mVp-p 200mVp-p
VOLTAGE ADJ. RANGE 3.2 ~ 3.5V 4.75 ~ 5.5V 11.4 ~ 13.2V 14.25 ~ 16.5V 22.8 ~ 26.4V 45.6 ~ 52.8V
VOLTAGE TOLERANCE Note.3 ±3.0% ±2.0% ±1.0% ±1.0% ±1.0% ±1.0%
LINE REGULATION Note.4 ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
LOAD REGULATION Note.5 ±2.0% ±1.0% ±0.5% ±0.5% ±0.5% ±0.5%
SETUP, RISE, HOLD TIME 500ms, 20ms, 100ms/230VAC  1200ms, 30ms, 18ms/115VAC at full load
INPUT VOLTAGE RANGE 88 ~ 264VAC          125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage)
FREQUENCY RANGE 47 ~ 63Hz
EFFICIENCY (Typ.) 74% 77% 81% 82% 84% 84%
AC CURRENT(Typ.) 2.5A/115VAC          1.5A/230VAC
INRUSH CURRENT (Typ.) COLD START 40A/230VAC
LEAKAGE CURRENT <2mA / 240VAC
PROTECTION OVERLOAD 110 ~ 150% rated output power
Protection type: Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE 3.8 ~ 4.45V 5.75 ~ 6.75V 13.8 ~ 16.2V 17.25 ~ 20.25V 27.6 ~ 32.4V 55.2 ~ 64.8V
Protection type: Hiccup mode, recovers automatically after fault condition is removed
ENVIRONMENT WORKING TEMP. -25 ~ +70ºC
WORKING HUMIDITY 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY -40 ~ +85ºC, 10 ~ 95% RH
TEMP. COEFFICIENT ±0.03%/ºC (0 ~ 50ºC)
VIBRATION 10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY & EMC(Note.6) SAFETY STANDARDS Design refer to UL60950-1, TUV EN60950-1
WITHSTAND VOLTAGE I/P-O/P:3KVAC   I/P-FG: 1.5KVAC   O/P-FG: 0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT Compliance to EN61000-3-2,-3
EMS IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61000-6-2 (EN50082-2) heavy industry level, criteria A
OTHERS MTBF 260.8Khrs min. MIL-HDBK-217F (25ºC)
DIMENSION 159*97*38mm (L*W*H)
PACKING 0.6Kg; 24pcs/15.4Kg/0.7CUFT
NOTE 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance: includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 0% to 100% rated load.
6. The power supply is considered a component which will be installed into final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.

100W Switching Power Supply RS-100 Mechanical

100W Switching Power Supply RS-100 Mechanical

100W Switching Power Supply RS-100 Certificate

LVD Certificate
100W Switching Power Supply RS-100 LVD Certificate
EMC Certificate
100W Switching Power Supply RS-100 EMC Certificate
RoHS Certificate
Switching Power Supply RS-rohs

Send messageclear