100W Switching Power Supply NES-100

100W Switching Power Supply NES-100

Features:

  • Universal AC input/Full range
  • Protections: Short circuit / Overload / Over voltage
  • Cooling by free air convection
  • 100% full load burn-in test

Description

100W Switching Power Supply NES-100 Technical Data

MODELNES-100-5NES-100-7.5NES-100-9NES-100-12NES-100-15NES-100-24NES-100-48
OUTPUTDC VOLTAGE5V7.5V9V12V15V24V48V
RATED CURRENT20A13.6A11.2A8.5A7A4.5A2.3A
CURRENT RANGE0 ~ 20A0 ~ 13.6A0 ~ 11.2A0 ~ 8.5A0 ~ 7A0 ~4.5A0 ~ 2.3A
RATED POWER100W102W100.8W102W105W108W110.4W
RIPPLE & NOISE (max.) Note.280mVp-p120mVp-p120mVp-p120mVp-p120mVp-p120mVp-p200mVp-p
VOLTAGE ADJ. RANGE4.75 ~ 5.5V7.13 ~ 8.3V8.55 ~ 9.9V11.4 ~ 13.2V14.25 ~ 16.5V22.8 ~ 26.4V45.6 ~ 52.8V
VOLTAGE TOLERANCE Note.3±2.0%±1.0%±1.0%±1.0%±1.0%±1.0%±1.0%
LINE REGULATION Note.4±0.5%±0.5%±0.5%±0.5%±0.5%±0.5%±0.5%
LOAD REGULATION Note.5±0.5%±0.5%±0.5%±0.5%±0.5%±0.5%±0.5%
SETUP, RISE, HOLD TIME500ms, 20ms, 30ms/230VAC,  500ms, 20ms, 25ms/115VAC at full load
INPUTVOLTAGE RANGE85 ~ 132VAC / 176 ~ 264VAC selected by switch           248 ~ 373VDC
FREQUENCY RANGE47 ~ 63Hz
EFFICIENCY (Typ.)80%81%81%83%84%86%86%
AC CURRENT(Typ.)2.5A/115VAC          1.5A/230VAC
INRUSH CURRENT (Typ.)COLD START 36A
LEAKAGE CURRENT<2mA / 240VAC
PROTECTIONOVERLOAD110 ~ 150% rated output power
Protection type: Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE5.75 ~ 6.75V8.6 ~10.1V10.4 ~ 12.2V13.8 ~ 16.2V17.25 ~ 20.25V27.6 ~ 32.4V55.2 ~ 64.8V
Protection type: Hiccup mode, recovers automatically after fault condition is removed
ENVIRONMENTWORKING TEMP.-20 ~ +60ºC
WORKING HUMIDITY20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY-40 ~ +85ºC, 10 ~ 95% RH
TEMP. COEFFICIENT±0.03%/ºC (0 ~ 50ºC)
VIBRATION10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY & EMC(Note.6)SAFETY STANDARDSDesign refer to UL60950-1, TUV EN60950-1
WITHSTAND VOLTAGEI/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCEI/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMI CONDUCTION & RADIATIONCompliance to EN55022(CISPR22) Class B
HARMONIC CURRENTCompliance to EN61000-3-2,-3
EMS IMMUNITYCompliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61000-6-2 (EN50082-2) heavy industry level, criteria A
OTHERSMTBF320.7Khrs min. MIL-HDBK-217F (25ºC)
DIMENSION159*97*38mm (L*W*H)
PACKING0.55Kg; 30pcs/17.5Kg/0.97CUFT
NOTE1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance: includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 0% to 100% rated load.
6. The power supply is considered a component which will be installed into final equipment. The final equipment must be re-confirmed that it still meets EMC directives.