100W PFC Power Supply SP-100

100W PFC Power Supply SP-100

Features:

  • Universal AC input / Full range
  • Built-in active PFC function, PF>0.93
  • Protections:Short circuit/Over load/Over voltage
  • Built-in constant current limiting circuit
  • Remote ON-OFF control(Optional)
  • LED indicator for power on
  • 100% full load burn-in test
  • Fixed switching frequency at PFC:67KHz PWM:134KHz

Description

100W PFC Power Supply SP-100 Technical Data

MODELSP-100-3.3SP-100-5SP-100-7.5SP-100-12SP-100-13.5SP-100-15SP-100-24SP-100-27SP-100-48
OUTPUTDC VOLTAGE3.3V5V7.5V12V13.5V15V24V27V48V
RATED CURRENT20A20A13.5A8.5A7.5A6.7A4.2A3.8A2.1A
CURRENT RANGE0 ~ 20A0 ~ 20A0 ~ 13.5A0 ~ 8.5A0 ~ 7.5A0 ~ 6.7A0 ~4.2A0 ~ 3.8A0 ~ 2.1A
RATED POWER66W100W101.25W102W101.25W100.5W100.8W102.6W100.8W
RIPPLE & NOISE (max.) Note.2100mVp-p100mVp-p100mVp-p100mVp-p100mVp-p100mVp-p150mVp-p150mVp-p250mVp-p
VOLTAGE ADJ. RANGE3.14 ~ 3.63V4.75 ~ 5.5V7.13 ~ 8.25V11.4 ~ 13.2V12.8 ~ 14.9V14.3 ~ 16.5V22.8 ~ 26.4V25.7 ~ 29.7V45.6 ~ 52.8V
VOLTAGE TOLERANCE Note.3±2.0%±2.0%±2.0%±2.0%±2.0%±2.0%±1.0%±1.0%±1.0%
LINE REGULATION±0.5%±0.5%±0.5%±0.5%±0.5%±0.5%±0.5%±0.5%±0.5%
LOAD REGULATION±1.0%±1.0%±1.0%±0.5%±0.5%±0.5%±0.5%±0.5%±0.5%
SETUP, RISE, HOLD TIME600ms, 30ms, 20ms at full load
INPUTVOLTAGE RANGE  Note.585 ~ 264VAC        120 ~ 370VDC
FREQUENCY RANGE47 ~ 63Hz
POWER FACTOR (Typ.)PF>0.93/230VAC      PF>0.98/115VAC at full load
EFFICIENCY (Typ.)70%76%78%80%80%82%84%83%82%
AC CURRENT(Typ.)1.7A/115VAC          0.8A/230VAC
INRUSH CURRENT (Typ.)COLD START 30A/230VAC
LEAKAGE CURRENT<2mA / 240VAC
PROTECTIONOVERLOAD105 ~ 150% rated output power
Protection type: Constant current limiting, recovers auto matically after fault condition is removed
OVER VOLTAGE3.8 ~ 4.46V5.75 ~ 6.75V8.25 ~ 10.13V13.2 ~ 16.2V14.85 ~ 18.23V16.5 ~ 20.25V26.4 ~ 32.4V29.7 ~ 36.45V52.8~ 64.8V
Protection type: Shut down o/p voltage, re-power on to recover
FUNCTIONREMOTE CONTROL (OPTION)CN1:4 ~10VDC POWER ON,<0 ~ 0.8VDC POWER OFF
ENVIRONMENTWORKING TEMP.-10 ~ +60ºC
WORKING HUMIDITY20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY-20 ~ +85ºC, 10 ~ 95% RH
TEMP. COEFFICIENT±0.05%/ºC (0 ~ 50ºC)
VIBRATION10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC(Note4)SAFETY STANDARDSDesign refer to UL60950-1,TUV EN60950-1
WITHSTAND VOLTAGEI/P-O/P: 3KVAC   I/P-FG: 1.5KVAC    O/P-FG: 0.5KVAC
ISOLATION RESISTANCEI/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMI CONDUCTION & RADIATIONCompliance to EN55022(CISPR22) Class B
HARMONIC CURRENTCompliance to EN61000-3-2,-3
EMS IMMUNITYCompliance to EN61000-4-2,3,4,5,6,8,11;EN50204,EN55024,Light industry level, criteria A
OTHERSMTBF191.2K hrs min. MIL-HDBK-217F (25ºC)
DIMENSION199*99*50mm (L*W*H)
PACKING0.76Kg; 20pcs/19.24Kg/1.28CUFT
NOTE1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance: includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into final equipment. The final equipment must be re-confirmed that it still meets EMC directives.

100W PFC Power Supply SP-100 Mechanical

100W PFC Power Supply SP-100 Certificate

LVD Certificate
EMC Certificate
100W PFC Power Supply SP-100 EMC Certificate
RoHS Certificate
PFC Power Supply RoHS

Send message