100W DC-DC Converter SD-100

100W DC-DC Converter SD-100

Features:

  • 2:1 wide input range
  • Protections: Short circuit/Over load/Over voltage
  • 1500VDC I/O isolation
  • Built-in EMI filter, low ripple noise
  • 100% full load burn-in test
  • Fixed switching frequency at 83KHz
  • 24V and 48V input voltage design refer to LVD
  • Low cost
  • High reliability

Description

100W DC-DC Converter SD-100 Technical Data

MODEL SD-100B-05 SD-100C-05 SD-100D-05 SD-100B-12 SD-100C-12 SD-100D-12 SD-100B-24 SD-100C-24 SD-100D-24
OUTPUT DC VOLTAGE 5V 12V 24V
RATED CURRENT 20A 8.5A 4.2A
CURRENT RANGE 0 ~ 20A 0 ~ 8.5A 0 ~ 4.2A
RATED POWER 100W 102W 100.8W
RIPPLE & NOISE (max.) Note.2 100mVp-p 120mVp-p 150mVp-p
VOLTAGE ADJ. RANGE 4.5 ~ 5.5VDC 11 ~ 16VDC 23 ~ 30VDC
VOLTAGE TOLERANCE Note.3 ±2.0% ±1.0% ±1.0%
LINE REGULATION ±0.5% ±0.3% ±0.2%
LOAD REGULATION ±0.5% ±0.3% ±0.2%
SETUP, RISE, HOLD TIME 2s, 50ms, 24ms(only D mode) at full load
INPUT VOLTAGE RANGE B:19 ~ 36VDC          C:36 ~ 72VDC          D:72 ~ 144VDC or 85 ~ 132VAC
EFFICIENCY (Typ.) 74% 75% 76% 75% 77% 80% 78% 81% 83%
DC CURRENT 4.8A/24V 2.4A/48V 1.8A/96V 4.8A/24V 2.4A/48V 1.8A/96V 4.8A/24V 2.4A/48V 1.8A/96V
INRUSH CURRENT (Typ.) D:18A/96VDC
LEAKAGE CURRENT <0.75mA/120VAC(SD-100D)
PROTECTION OVERLOAD 105 ~ 135% rated output power
Protection type: Fold back current limiting, recovers automatically after fault condition is removed
OVER VOLTAGE 5.75 ~ 6.75V/10% load 16.8 ~ 20V/10% load 31.5 ~ 37.5V/10% load
Protection type: Hiccup mode, recovers automatically after fault condition is removed
ENVIRONMENT WORKING TEMP. -10 ~ +60ºC
WORKING HUMIDITY 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY -20 ~ +85ºC, 10 ~ 95% RH
TEMP. COEFFICIENT ±0.03%/ºC (0 ~ 50ºC)
VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY &EMC (Note 4) SAFETY STANDARDS Design refer to EN60950-1 CB, TUV
WITHSTAND VOLTAGE I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMI CONDUCTION & RADIATION Design refer to EN55022(CISPR22) CLASS B
EMS IMMUNITY Design refer to EN61000-4-2,3,4,6,8; ENV50204, EN55024, light industry level, criteria A
OTHERS MTBF 356.7K hrs min.(SD-100B)          355.5K hrs min.(SD-100C)          341.9K hrs min.(SD-100D)      MIL-HDBK-217F (25ºC)
DIMENSION 199*98*38mm (L*W*H)
PACKING 0.65Kg; 20pcs/13.8Kg/0.8CUFT
NOTE 1. All parameters NOT specially mentioned are measured at normal input, rated load and 25ºC of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance: includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.

100W DC-DC Converter SD-100 Mechanical

100W DC-DC Converter SD-100 Mechanical

100W DC-DC Converter SD-100 Certificate

LVD Certificate
100W DC-DC Converter SD-100 Certificate
EMC Certificate
100W DC-DC Converter SD-100 EMC Certificate
RoHS Certificate
DC-DC Converter RoHS Certificate

Send messageclear